Analyte | Certified Value | 1SD | 95% Confidence Limits Low | 95% Confidence Limits High | Method |
---|---|---|---|---|---|
P2O5, Phosphorus(V) oxide (wt.%) | 12.97 | 0.207 | 12.82 | 13.13 | Borate Fusion XRF |
Al2O3, Aluminium(III) oxide (wt.%) | 7.08 | 0.081 | 7.02 | 7.13 | Borate Fusion XRF |
CaO, Calcium oxide (wt.%) | 17.60 | 0.142 | 17.49 | 17.71 | Borate Fusion XRF |
Fe2O3, Iron(III) oxide (wt.%) | 3.48 | 0.024 | 3.47 | 3.50 | Borate Fusion XRF |
K2O, Potassium oxide (wt.%) | 0.600 | 0.012 | 0.592 | 0.608 | Borate Fusion XRF |
MgO, Magnesium oxide (wt.%) | 0.678 | 0.032 | 0.656 | 0.701 | Borate Fusion XRF |
MnO, Manganese oxide (wt.%) | 0.047 | 0.007 | 0.042 | 0.052 | Borate Fusion XRF |
Na2O, Sodium oxide (wt.%) | 0.183 | 0.020 | 0.168 | 0.198 | Borate Fusion XRF |
SiO2, Silicon dioxide (wt.%) | 52.82 | 0.358 | 52.55 | 53.10 | Borate Fusion XRF |
TiO2, Titanium dioxide (wt.%) | 0.420 | 0.013 | 0.411 | 0.429 | Borate Fusion XRF |
LOI1000, Loss On Ignition @1000°C (wt.%) | 3.08 | 0.204 | 2.90 | 3.27 | Thermogravimetry |